What this tool solves
A wider seal specimen may take more force to open without having a higher peak force per unit width. Normalize measured peel peaks to a common width basis to spot individual strips that merit review, instead of comparing raw loads or relying on a batch mean alone.
How to choose the inputs
Use the width of the cut test strip along the seal, not the seal band depth. Enter one peak force per strip using a common support technique, speed, and conditioning. The optional threshold is a number your operation already uses for this same reporting basis; leave it blank if there is none.
How the calculation works
Convert each peak to newtons and divide by strip width in millimeters. Multiply by 15 for N/15 mm. To express the same force per width in lbf/in, multiply N/mm by 25.4 and divide by 4.4482216152605. Compare individual unrounded N/15 mm readings to the entered threshold.
Worked example
A 15 mm strip at 6 N and a 25 mm strip at 11 N normalize to 6 and 6.6 N/15 mm. The third example strip is 5.4 N/15 mm, so the mean is 6 N/15 mm but one of three strips is below the 6 N/15 mm review threshold.
How to interpret the output
An exact threshold match is not counted below it. A strip below a user threshold is a review flag only. The worksheet averages specimen peaks, which is different from an instrument’s average peel force along a seal. Keep observed failure modes with the original report.
Common mistakes
- Do not enter a value that is already in N/15 mm as though it were raw newtons.
- Do not mix unsupported and supported peel techniques in the same comparison.
- Do not infer that a strong peel reading means the whole package is leak-free.
Assumptions and limitations
This review does not prescribe a minimum seal strength, classify failure modes, demonstrate ASTM F88 compliance, or replace leak testing or the applicable release procedure.
Related workflow and sources
Check the method context for review seal peel before you compare measurements.